Our Infrastructure

Integrated Setup

  • Aluminium Ingot Storage

  • Clean Liquid Metal Transfer

  • DM-650 - with ladel, sprayer & extractor

  • DM-180 - with ladel, sprayer & extractor

  • Pretreatment Plant - Aluminium

  • Pretreatment Plant - MS

  • Conveyorised Powder Coating Plant

  • Powder Coating Batch Production Plant

  • Luminaire Assembly - 1st Floor

  • Luminaire Assembly - 3rd Floor

  • LED Luminaire Assembly (ESD) Area

  • LED Luminaire Assembly (ESD) Area

Testing Facility

  • PC BASED LED MODULE TEST EQUIPMENTS
    1.Insulation (Megger) Test at 500V
    2. Run Test to measure DC Voltage and DC Current
    3. High Voltage Test at 3KV max
    4. NTC Resistance check test
    All tests are performed as per IS 16103 Part 1 & 2.
    Tests will be automatically carried out, controlled by PLC and test result will be transferred to data logging and reports will be generated.

  • PC BASED DRIVER TEST EQUIPMENTS
    1.HIGH VOLTAGE TEST at 1500 V AC - a.Between Input and, b.Between Luminaires body and Input output terminals shorted together
    2.Performance Test - a.Low voltage Cut off test, b.Low voltage performance test, c.Nominal voltage performance test, d.Driver efficiency calculation, e.THD at Input supply test, f.Open circuit output DC Voltage test, g.High – voltage cut off test
    All tests are performed as per IS 15885 Part 1 IS 15885
    (Part 2) sec – 13 and IS 16104.Tests will be automatically carried out, controlled by PLC and test result will be transferred to data logging and reports will be generated.

  • PC BASED LUMINAIRE TEST EQUIPMENTS
    1.Earth Bond test - 10 Amps – 10V
    2.High voltage test at 1500V AC
    3.Insulation resistance test
    4.Leakage current test
    5.Lamp burning test
    6.Performance test
    7.Low voltage Cut off test
    8.Low voltage performance test
    9.Nominal voltage performance test
    10.High voltage performance test
    11.Earth leakage current test
    12.High – voltage cut off test
    All tests are performed as per IS 16107 (Part 2 / sec 1) and IS 10322.Tests will be automatically carried out, controlled by PLC and test result will be transferred to data logging and reports will be generated.

  • Power Analyzer Test Equipment
    1. Earth Bond test - 10 Amps – 10V, 2. High voltage test at 1500V AC, 3.Insulation resistance test, 4.Leakage current test, 5.Lamp burning test, 6.Performance test, a.Low voltage Cut off test, b.Low voltage performance test, c.Nominal voltage performance test, d.High voltage performance test, e.Earth leakage current test, f.High – voltage cut off test
    All tests are performed as per IS 16107 (Part 2 / sec 1) and IS 10322.Tests will be automatically carried out, controlled by PLC and test result will be transferred to data logging and reports will be generated.

  • Surge generator Test equipment
    Surge generator is specifically designed for simulating lighting strike and produces large energy like high voltage, high current. All surge tests are performed as per IEC 61000 – 4 -5, EN 61000 – 4 -5 and GB / T 17625.5

  • Integrated sphere with Spectro radio meter equipment
    Spectral, colorimetric & Electric testing of lamps and luminaires.
    a. Luminous flux (lm)
    b. Luminous Efficacy
    c. Spectral power distribution
    d. CCT
    e. CRI (Ra, Ri (i = 1~15)
    f. Radiant power
    g. Peak wave length
    h. Dominant Wavelength
    i. Spectra half width
    j.Colorimetric purity
    k. SCDM (Standard deviation of color matching)
    All tests are performed as per IS 16106 and IES LM -79-08

  • Spectral irradiance colorimetric meter
    This is handy system used for Spectral, colorimetric & Electric testing of lamp & luminaires.
    a. Luminous flux (lm)
    b. Luminous Efficacy
    c. Spectral power distribution
    d. CCT
    e. CRI (Ra, Ri (i = 1~15)
    f. Radiant power
    g. Peak wave length
    h. Dominant Wavelength
    i. Spectra half width
    j.Colorimetric purity
    k. SCDM (Standard deviation of color matching)
    All tests are performed as per IS 16106 and IES LM -79-08

  • Illuminance meter (Lux meter)
    This handy system is used to quickly test relative
    a. Luminous flux (lm) lamps & luminaires
    b. Illuminance difference
    c. Illuminance proportion
    d. Integrating illuminance
    e. Average illuminance.
    It is basically used on site lux measurements

  • Goniophotometer - FULL FIELD SPEED – EVERFINE GO-R5000 (AS PER LM-79/IS16106)
    GO-R5000 can be widely used in the measurement of all types of lighting sources like lamps, luminaires, indoor lights, outdoor lights, street lights, flood lights with very high accuracy. Export format: *.GOS *.CIE *.CEN *.IES *.TM14 *.CIB *.LDT, which can directly match International Universal Lighting Design Software, such as Dialux, AGI32, Lumen-Micro. The spatial spectral/colorimetric quantities and spectral/color uniformity and luminance distribution and luminance uniformity can be achieved by the goniophotometer system. Fully meets IESNA LM-79 and GB/T 24824.

  • WATER INGRESS TEST EQUIPMENT
    Water Ingress Testing is conducted to ensure the product is able to operate safety in it’s intended end use. Depending on the intended use the test may involve dripping, Spraying or Submerging the product under water. Depending on the water ingress code IX4 /X5 and Ix6 tests may be conducted. This is the performance and reliability test of the luminaire. All Tests are Performed with respect to IEC 60529

  • LUMINAIRE SOAKING TEST EQUIPMENT
    This is the Reliability Test of the luminaire. All LED luminaires are subjected to work under various input voltage conditions i.e. Low Voltage, Nominal Voltage and High Voltage as well as with ON / Off test to simulate the power failures and highspikes when power re connects. This is the Performance Reliability Test of the luminaire.

Contact

413, Orion Business Park,
Ghodbunder Road, Kapurbawdi,
Thane(W) - 400607
Maharashtra, India.

TeL : - 9819130009
Email :- info@argolighting.in

Visit our social media handles today to know more about what we have to offer.

Our Catalog

© Copyright 2020 Argo Lighting | All Rights Reserved.

Developed and Maintained By: Aspiring Media Tech Pvt. Ltd.